Vented against your dust, not a table
We use the measured Kst and Pmax of your material to calculate vent area to EN 14491 and NFPA 68.
Pulse-jet baghouses, cartridge collectors and cyclones delivering outlet emissions below 5 mg/Nm³ with ATEX-compliant explosion protection.
Overview
A dust collector is two systems sharing a housing: a filtration system that must meet an emission limit, and a safety system that must contain a deflagration. Designing one without the other is how dust collectors become incidents.
CYCLA collectors are designed against the measured Kst and Pmax of your actual dust, not a generic table value. Vent area is calculated to EN 14491 and NFPA 68, and where venting to atmosphere is not possible, we specify flameless venting or chemical suppression.
On the filtration side, can velocity governs whether a baghouse works. Too high and dislodged dust re-entrains onto adjacent bags instead of falling to the hopper, and the collector never recovers its clean differential pressure. We hold can velocity below 1.5 m/s as design practice.
Configurations
CYCLA-BH
Pulse-jet baghouse for high-volume, high-temperature process dust.
CYCLA-CT
Cartridge collector with pleated media for fine dust in a compact footprint.
CYCLA-CY
Cyclone pre-separator for coarse and abrasive bulk loading.
CYCLA-WT
Wet scrubber for combustible metal dust and sticky particulate.
CYCLA-ATX
Fully ATEX-certified assembly with venting, isolation and earthing scheme.
We use the measured Kst and Pmax of your material to calculate vent area to EN 14491 and NFPA 68.
Correct hopper and inlet geometry lets dislodged dust fall rather than re-entrain, keeping the clean differential pressure stable for years.
Differential-pressure-triggered pulsing cuts compressed-air consumption 40–60% against fixed-interval cleaning and doubles bag life.
Outlet concentration is a performance guarantee verified by isokinetic stack sampling at handover.
Applications
Industries
Technical drawings
Collector general arrangement
Housing, hopper, fan and stack with structural interfaces.
Bag and cage schedule
Quantity, dimensions, media and finish per compartment.
Explosion venting layout
Vent panel positions, areas and safe discharge envelope.
Ducting and hood design
Capture velocities, transport velocities and branch balancing.
Next step
Send flow, contaminant, rating, chemistry and available pressure. We return a configuration with the sizing basis attached.
Or call +91 79 4890 2200 · sales@worldasatech.com